Leading Manufacturers, Exporters, Wholesaler of PI 590-1 Digital Process Indicator, PI541A 6 Digit Process Indicator and PI542A 4 Digit Process Indicator from Chennai.
SANSEL offers are extremely versatile Indicators that can be used for a wide variety of applications.These Universal indicator offer high precision 6 digit resolution & extreme reliability and low cost for Process measurement. PI541A is a Microprocessor based instrumentation ensures accurate readings for all Linear Parameters, RTD, ohms & different type of Thermocouples. A number of programmable features including In-line calibration are standard. PI541A can offer relay outputs for signals exceeding set points, optional Programmable 4 -20mA or 0 - 10V DC Isolated output and also Optional RS 485 (2 wire ) MODBUS protocol output is provided .
Features
6 Digit 7 segment red LED display
High Accuracy
Compact Size
24 Bit ADC Resolution
Wide Selectable Range between -199999 to 199999 counts
Selectable Inputs RTD, all types of thermocouples, mA, mV,Voltage & ohms.
Easy Field Configurable with Front Key Calibration
No Hardware Selection for the Input Signals
Optional Opto Isolated Re-Transmission Output
Optional RS 485 (2 wire) MODBUS protocol
24V DC External Sensor Excitation Supply
Programmable Decimal Point & Display Noise Filter
Universal Supply Voltage 90 to 270 AC / DC
Specifications :
Display 6 Digit 7 segment red LED
Inputs 0 - 20 mA, 0 to 75 mV, -10 to 10 V DC, 0 - 400 Ù (H & L Limit Programmable)
RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Range* Analog - - 199999 to 199999 (H & L Limit Programmable)
RTD &TC - RTD - PT 100 (-199 to 850°C / 327 to 1562°F)
RTD - PT 1000 (-50 to 400°C / -58 to 752°F)
TC - J (- 200 to 200°C / -328.0 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999 °C / -327 to 1832°F)
Resolution 0.0001 / 0.001 / 0.01 / 0.1 / 1 Selectable for Analog
0.01 RTD - PT 100 and 0.1 for TC
Accuracy ± 0.01 % of FS for Analog , ± 2 °C for TC and better than ± 0.2°C for RTD
SANSEL offers PROCESS INDICATORs are extremely versatile Indicators that can be used for a wide variety of applications. These INSTRUMENT offer extreme reliability and low cost for Process measurement and logging. PI 542A is a Microprocessor based instrumentation ensures accurate readings for all Linear Parameters. A number of programmable features including In-line calibration are standard. All the parameters are saved in a non volatile EEPROM memory which doesn't needs any external battery. PI 542A can offer relay outputs for signals exceeding set points. Programmable Re Transmission output models are also available in addition to the industry standard 4 -20mA or 0 - 10V DC output. Optional RS 485 (2 wire ) output also provided for PC communication with PC Interface software & also with MODBUS RTU protocol.
Features
4 Digit 7 segment RED LED display
High Accuracy
Compact Size
24 Bit ADC Resolution
Selectable Inputs RTD , all types of thermocouples , mA, mV , Voltage , ohms.
Wide Selectable Range between -1999 to 9999 counts
Easy Field Configurable with Front Key Calibration
No Hardware Selection For the Input Signals
Optional Opto Isolated Re Transmission Output.
Optional RS 485 (2 wire) Output for PC communication
Optional PC software with Monitoring, Logging, Report & Graph
Optional MODBUS RTU protocol
24V DC External Sensor Supply
Programmable Decimal Point & Display Noise Filter
Universal Supply Voltage 90 to 270 AC / DC
Specification
Display 4 Digit 7 segment RED LED
Analog Inputs 0 - 20 mA, 0 to 75 mV, -10 to 10 V DC, 0 - 400 Ù (H & L Limit Programmable)
Temperature Inputs RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog Display Range* - 1999 to 9999 (H & L Limit Programmable)
Temperature Range RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 1562°F)
(H & L Limit Programmable) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0°F)
TC - J (- 200.0 to 200°C / -328.0 to 2192°F)
TC - K (- 200.0 to 1372°C / -327.8 to 2501°F)
TC - R (- 40.0 to 1768°C / -40.0 to 3214°F)
TC - S (- 40.0 to 1768°C / -40.0 to 3214°F)
TC - T (- 200.0 to 400°C / -328.0 to 752°F)
TC - B (300.0 to 1820°C / 572.0 to 3308°F)
TC - N (-200.0 to 1300°C / -327.8 to 2372°F)
TC - E ( -200.0 to 999.9°C / -327.8 to 1832°F)
Unit selection °C / °F (for RTD & TC inputs)
Analog Resolution 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature Resolution 0.01(for RTD-PT 100 input(°C) only) / 0.1 / 1 °C / °F
Accuracy ± 0.1 % of FS
Filter Constant 1 - 100 % (Adjustable)
Relay Output**(optional) 2 Relay
Re Transmission**(optional) Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC Communication** RS 485 (2 wire)(optional)
PC Software**(optional) Monitoring, Data Logging, Report & Graph
Sensor Supply(external) 24 V DC ±10% @ 100 mA
(5A rated) with Four Relay Status Selection, Hysterisis, Cyclic Delay
Operating Environment 0 - 50ºC / 5 to 95 % RH Non Condensing